Application:
Acid Gas Injection of Liquid H2S/CO2
Location:
Wapiti Area (Alberta, Canada)
Objective:
Injection pressure of 95% H2S & 5% CO2 precluded the use of a 6-stage compressor due to condensing temperature on interstage. A 5-stage compressor was used, with the process being condensed and sub-cooled prior to the last pumping stage.
Design Challenges:
A “seal-less” double diaphragm tri-plex pump was selected for this application. Maintaining correct NPSH requirements for the pump in this critical service, while minimizing costs through sub-cooling. Correctly designing the accumulator to work with the 5-stages of compression, and the last pumping stage.
Major Equipment Specifications
Pump
LEWA G3M
Drive
Baldor 200 HP, 480V/3Ph/60Hz, 10:1 VFD motor
Air Cooler
AXH 108AEF condenser/sub-cooler
Control Panel
Spartan Allen-Bradley MicroLogix PLC processor
Other Features
Fully automated controls for minimal operator interface due to the nature of the process.
COMPASS MODEL NO: EM200-P-L-G3M