Retrofit

400 HP, 3-Stage, Reciprocating Compressor Package (Retrofit)

Application:

Retrofit fire-damaged compressor package

Location:

Central Alberta

Objective:

Refurbish burned compressor unit for deployment back into the rental fleet

Project Scope:

  • Replace the following due to fire damage:
    • Building interior
    • Building lighting, LEL, fire detection, exhaust fans
    • All instrumentation, electrical and end devices above grating
    • Control panel
    • PSVs
  • Overhaul compressor
  • Replace engine
  • Test vessels and process piping (hardness & UT)

Major Equipment Specifications

Compressor:

Ariel JGJ/4

Driver:

Waukesha F18GL

Air Cooler:

Air-X-Hemphill 108AEF

Control Panel:

MicroLogix 1400 PLC

Compass Model No: WK400-RAJ4-3

Contact Us