Process

Glycol System

Application:

Natural gas field processing for dewpoint control of natural gas.

Objective:

Increase ability of existing hydrocarbon dewpoint control plant and prevent hydrate formation during refrigeration.

Design Challenges:

Allow for integration of new equipment into existing plant while minimizing process upset and utility of site equipment.

Compass Solution:

Liquid/liquid LTS design (allowed for use of existing LTS for gas/liquid separation) and hydrate suppression injection for new and existing equipment.

Major Equipment Specifications

Vessels

  • 48” OD liquid/liquid LTS
  • 36” OD glycol flash vessel
  • 36” OD glycol carbon filter
  • Dual 6-5/8” glycol particle filter

Exchangers

  • 36” OD reboiler
  • 32” OD accumulator with coil type lean/ rich exchanger
  • 16” OD still column
  • 14” OD, 0.6 MM Btu/hr natural gas fired flame arrested fire-tube

Other Features

(2) 100% 15 HP Reciprocating Glycol Charge Pumps, 2290 psig discharge pressure.

Control Panel

Profire 2100 BMS

COMPASS MODEL NO: LTS AND ETHYLENE GLYCOL REGENERATION SYSTEM

Contact Us

North America Toll Free: 1-855-262-2487