Application:
Vapour Recovery Unit with skim pump and desand water pump
Location:
Northeastern BC
Objective:
To design and build a single package for VRU, skim pump and desand water pump, versus multiple packages.
Design Challenges:
High sour, shipping restrictions and required OH&S operator access.
Compass Solution:
A single package with dimensions of 20’ wide x 39’ long
Major Equipment Specifications
Compressor:
RoFlo 8D rotary vane
Drive:
Teco 50 HP @ 1200 RPM
Air Cooler:
- AIC Flate Plate for gas cooling
- AXH 42VI Air Cooler for glycol cooling
Control Panel:
MicroLogix 1400 PLC based control pane
Other Features:
- 16” OD horizontal inlet suction scrubber w/ liquid drain pump
- 20 HP Moyno skim pump c/w Plan 52 seal
- Wildon diaphragm recycle pump
- 100 HP Weatherford W165L triplex desand water pump c/w desand bag filter